Estimated Lead Time: 4–6 Weeks

  • 2 Ton: 24,000 BTU/hr
  • 5 Ton: 60,000 BTU/hr
  • 1 Year Warranty Included
  • Proudly Made in Tennessee, USA
  • Outdoor Rated & Pad Mount Ready

For orders outside of the continental US, please call us at 1-865-214-6509 or email us at support@penguinchillers.com.

From $7,499.99

Pay Over Time with Bread Pay™
 

About This Product:

Our Split Commercial Water Chillers are built for demanding cooling applications that require dependable performance, durable construction, and flexible configuration options. Available in 2 Ton and 5 Ton models, these outdoor-rated units are built on a stainless steel frame and are pad mount ready for commercial and industrial installations. Multiple heat exchanger options are available to help match your system’s fluid compatibility and operating requirements.

*Please note: the product photo shown in this listing is our 5 Ton Split Commercial Water Chiller. The 2 Ton model will appear slightly different with a smaller condenser.*

⚠️ Professional installation required: This split system must be hooked up by a licensed HVAC professional.

More Info:

Specifications
2 Ton
5 Ton
Cooling Capacity (BTU/hr)
24,000
60,000
Inlet / Outlet
1.5″ Slip Connections
1.5″ Slip Connections
Heat Exchanger Options
Copper, Titanium, 316 SS Shell & Coil
Copper, Titanium, 316 SS Shell & Coil
Voltage
208–240V
208–240V
Amps
17.7A
35.6A
Phase
Single Phase
Single Phase
Condenser (W × D × H)
27″W × 27″D × 34″H
32″W × 32″D × 45″H
Condenser Weight
150 lbs
215 lbs
Evaporator (W × D × H)
8″W × 42″D × 24″H
8″W × 42″D × 37″H
Evaporator Weight
85 lbs
100 lbs
Condenser Build
Outdoor Rated / Pad Mount Ready
Outdoor Rated / Pad Mount Ready
Frame
Stainless Steel Frame
Stainless Steel Frame
Warranty
1 Year Product Warranty
1 Year Product Warranty

Heat Exchanger Options
Copper Heat Exchanger
  • A dependable option for many general-purpose water cooling applications.
  • Copper heat exchanges are not recommended for closed loop reef/aquarium applications. Choose titanium for reef-safe systems.
  • Suitable for working pressures up to 10 PSI
Titanium Heat Exchanger
  • Recommended for applications where copper exposure is a concern.
  • Reef Tank Safe and highly corrosion resistant.
  • Ideal for marine, reef, and other sensitive water systems.
  • Suitable for working pressures up to 10 PSI
316 Stainless Steel Shell & Coil
  • Designed for higher pressure applications.
  • Suitable for working pressures up to 50 PSI.
  • Also available for anodizing baths containing up to 15% sulfuric acid.

Pump Recommendations
Recommended Pump: Danner Magnetic Drive 2400 GPH – 3600 GPH
  • Other pumps may be acceptable, however they must be rated for less than 10 PSI max pressure (for PVC shell heat exchanger only).
  • If you’re using a pool/spa pump or another pump rated in horsepower, check compatibility before installation. (for PVC shell heat exchanger only).
  • There is often a simple workaround that allows our chillers to cool higher pressure systems successfully. please contact support for more information.

Controller Notes
  • The controller constantly monitors your system’s incoming water temperature, therefore water flow is needed at all times to read current temperatures accurately.
  • When your water temperature rises above your desired set point, the controller tells the compressor to turn on and begin cooling.
  • Once your desired set point temperature is reached, the compressor will turn off.

Manufacturer Guidelines
  • Professional installation required: Split units must be connected by a licensed HVAC professional prior to use.
  • Outdoor rated / pad mount ready: Install on a stable, level surface with adequate clearance for airflow.
  • Continuous water flow is required for proper temperature monitoring and operation.
  • Units include a built-in flow switch designed to disable the chiller in the event of pump failure.
  • Copper option notice: Copper heat exchangers are not recommended for closed loop reef/aquarium applications. Choose titanium for reef-safe systems.
  • Condensation may occur depending on operating temperature and ambient humidity; plan your installation accordingly.

Split Commercial Water Chiller Size Comparison:
Model BTU/hr Connections Electrical Condenser Evaporator
2 Ton 24,000 1.5″ Slip 208–240V / 17.7A / Single Phase 27″W × 27″D × 34″H / 150 lbs 8″W × 42″D × 24″H / 85 lbs
5 Ton 60,000 1.5″ Slip 208–240V / 35.6A / Single Phase 32″W × 32″D × 45″H / 215 lbs 8″W × 42″D × 37″H / 100 lbs

2 Ton
BTU/hr
24,000
Connections
1.5″ Slip
Electrical
208–240V / 17.7A / Single Phase
Condenser
27″W × 27″D × 34″H / 150 lbs
Evaporator
8″W × 42″D × 24″H / 85 lbs
5 Ton
BTU/hr
60,000
Connections
1.5″ Slip
Electrical
208–240V / 35.6A / Single Phase
Condenser
32″W × 32″D × 45″H / 215 lbs
Evaporator
8″W × 42″D × 37″H / 100 lbs

American Owned and Operated
Penguin Chillers manufactures chillers in Knoxville, Tennessee USA and is an official member of the Made in Tennessee program, recognizing products built locally with verified Tennessee craftsmanship.
Have questions about which configuration is right for your setup? We’re here to help.
Call us during business hours to connect with a real person at our Knoxville office.

Related Products